From ebbeebd5875230fde0c0f4b5bc624fc7743815df Mon Sep 17 00:00:00 2001 From: "dragan.olcan" Date: Sat, 25 Jan 2025 18:46:03 +0100 Subject: [PATCH] Update Hardware_development/Measurements/v01/Flyback_1.txt --- Hardware_development/Measurements/v01/Flyback_1.txt | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/Hardware_development/Measurements/v01/Flyback_1.txt b/Hardware_development/Measurements/v01/Flyback_1.txt index 0d090a6..22ee50e 100644 --- a/Hardware_development/Measurements/v01/Flyback_1.txt +++ b/Hardware_development/Measurements/v01/Flyback_1.txt @@ -3,7 +3,7 @@ freq - frequency in Hz 7.40 - excitation from two batteries in series (7.40V) In no case the current from excitation is allowed to go above 2A. In no experiment the current is observed to be above 1.5A. The results in tables are output voltages measured at 1000:1 HV probe, hence the output voltage is given in kV. -Flyback configuration with TIP122 NPN transistor with 330 Ohms resitor in base is used. +Flyback configuration with TIP122 NPN transistor with 330 Ohms resistor in base is used. Single cascade is used with 30 capacitors and 60 (30x two-in-series) diodes 1N4007. ETD49 core with 4 isolated layers as secondary, no gaps and 3-turn primary