@ -42,3 +42,16 @@ AWG14 / 1.67mm dia., 5690V HY, 54m
|
|||
AWG18 / 1.02mm dia., 5130V HY, 137m
|
||||
AWG24 / 0.51mm dia., 4400V HY, 549m
|
||||
AWG34 / 0.16mm dia., 2630V HY, 2220m
|
||||
|
||||
Due to the fact that no commercially available trafos are found that satisfy the needs of O-ESD five new trafos are produced (trafos_2024-11.jpg).
|
||||
1) Core: ETD49/25/16 with 12 isolated layers of AWG 34 wire for secondary coil.
|
||||
2) Core: ETD29/16/10 with 10 isolated layers of AWG 34 wire for secondary coil.
|
||||
3) Core: ETD29/16/10 with 20 non-isolated layers of AWG 34 wire for secondary coil.
|
||||
4) Core: EF20/10/6 with 6 isolated layers of AWG 34 wire for secondary coil.
|
||||
5) Core: EF20/10/6 with 12 non-isolated layers of AWG 34 wire for secondary coil.
|
||||
Isolation between layers is 0.2mm high-voltage isolation paper for secondary coil.
|
||||
|
||||
Primary coil for each trafo is made from 2 to 16 turns of isolated wire. The number of turns is varied in order to get the best performances.
|
||||
|
||||
For push-pull configuration two primaries with center-tap are made.
|
||||
|
||||
|
|