Update Hardware_development/Measurements/v01/Readme.txt

This commit is contained in:
Dragan Olćan 2025-01-25 18:49:28 +01:00
parent 0de4787c01
commit 32d8d704bd

View file

@ -1,6 +1,6 @@
This folder contains measurement results for prototypes v0.1 of high-voltage generator based on all considered topologies.
We mix-and-match topologies previous termed as (1) flyback, (2) push-pull and (3) audio, with various trafos, cascades (single or double) and different power supplies in order to achieve as high as possible output voltage. While there are many combinations that were tested, documented ones are only those that have significant impact to the design decisions.
We mix-and-match topologies previously termed as (1) flyback, (2) push-pull and (3) audio, with various trafos, cascades (single or double) and different power supplies in order to achieve as high as possible output voltage. While there are many combinations that were tested, documented ones are only those that have a significant impact on the design decisions.
The results in tables are output voltages measured using 1000:1 high-voltage probe connected to DC voltmeter, hence the output voltage is given in kV. The frequency of switching flyback/push-pull or the input signal to the audio amplifier is varied. Hence, all the results are given as a function of frequency.
@ -23,4 +23,4 @@ A document with measured results for shapers can be found in shapers.pdf. Since
O-ESD > Hardware development > 5-Shapers > Shaper1_v1 and
O-ESD > Hardware development > 5-Shapers > Shaper7_v2.
Finally, the decisions are made taking into the account all the gathered information and are summarized in Design_decisions.txt file.
Finally, the decisions are made taking into account all the gathered information and are summarized in Design_decisions.txt file.